Fixture flow limits, Civil Code 1101.4, safety glass, exhaust fans, GFCI outlets and shower size: the 2025 code rules a bath remodel has to meet.

October 15, 20264 min read

Most bathroom remodels need a permit. Pasadena's 2025 handout requires one when you remove, replace or move a vanity, toilet, sink, tub or shower, replace or alter the electrical, or replace the wallboard; new towel bars, mirrors or paint don't need one. Pasadena issues bath permits through its Permit Center, and other cities keep similar lists. Once you have a permit, the 2025 California codes apply to the work, as they have for every permit filed since January 1, 2026.

Water: the fixtures and the whole-house rule

California's green building code (CALGreen) caps the water use of every new fixture:

  • Toilets: 1.28 gallons per flush at most.
  • Showerheads: 1.8 gallons per minute at 80 psi. With more than one showerhead, the combined flow from one valve can't pass 1.8 gallons per minute, or the shower has to run one outlet at a time.
  • Bathroom faucets: 1.2 gallons per minute at most at 60 psi, and at least 0.8 at 20 psi.

California Civil Code 1101.4 reaches past the bathroom. For any permitted alteration to a single-family home built on or before January 1, 1994, the building department won't sign off the final until every noncompliant fixture in the house has been replaced. The law defines noncompliant as a toilet made for more than 1.6 gallons per flush, a showerhead over 2.5 gallons per minute, or an interior faucet over 2.2 gallons per minute. So the old toilet in the hall bath can hold up the final on your primary bath. Count those fixtures when you set the budget.

Shower size, valves and surfaces

The 2025 California Plumbing Code sets the shower's minimum size. The finished interior needs at least 1,024 square inches of floor area and room to fit a 30-inch circle, and that space has to stay clear up to 70 inches above the drain, apart from the valve, showerhead, shelves and grab bars. A receptor at least 30 inches wide and 60 inches long, the size of a standard tub, is exempt from the minimum.

Every shower and tub-shower needs a pressure-balance or thermostatic valve that protects against scalding, set so the water leaving the showerhead stays at or under 120°F. The walls around a shower, and above a tub with a showerhead, need a nonabsorbent finish at least 6 feet above the floor.

Pasadena's 2025 handout adds the plumbing clearances: 30 inches of clear width for a toilet, 15 inches from its centerline to each side, and 24 inches of clear space in front of a toilet or sink. It also asks for shower doors that open out, with an opening at least 22 inches wide.

Glass near the tub and shower

The 2025 California Residential Code treats glass in the walls or enclosure of a tub or shower as a hazardous location when its bottom edge sits less than 60 inches above the standing surface. That glass, including a window over the tub, has to be safety glazing. Glass more than 60 inches away, measured horizontally from the water's edge, is exempt. An old window beside a tub may be plain glass, so check it before tile goes up around it.

Air and light

Every bathroom with a tub or shower needs an exhaust fan for humidity control, and an open window doesn't count. Under CALGreen the fan has to be ENERGY STAR rated, ducted to the outside, and run by a humidity control you can set between 50 and 80 percent relative humidity, unless the fan is part of a whole-house ventilation system. The Residential Code sets the minimum at 50 cubic feet per minute when the fan runs on demand, or 20 when it runs continuously, and some cities ask for more on a continuous fan.

For lighting, LA County cities' 2025 checklists ask for:

  • High-efficacy fixtures throughout the bathroom.
  • At least one fixture controlled by an occupancy or vacancy sensor that turns it off.
  • An exhaust fan on its own switch, separate from the lights.
  • Recessed fixtures rated for insulation contact, airtight and sealed to the ceiling.

Outlets and circuits

The bathroom gets at least one 20-amp receptacle within 36 inches of the outside edge of each sink, no more than 12 inches below the counter. One or more 20-amp circuits feed the bathroom receptacles and serve no other outlets, though one circuit may serve more than one bathroom. Every 15- and 20-amp receptacle in the room needs ground-fault (GFCI) protection and a tamper-resistant listing. Light fixtures over the tub or shower need a damp or wet location rating, depending on where they sit.

How we handle a bathroom remodel

Bathrooms are among the jobs we're asked for most at Kabaian Projects. As the general contractor, we run the whole bath, from demolition through the final inspection. Nareg Kabaian supervises the work on site every day, and we answer calls and texts 24/7 while your bathroom is out of service. The bathroom remodeling page covers what a bath job with us includes. If your house is older, read our post on lead-safe work in pre-1978 homes too: demolishing painted walls always falls under the EPA's lead rule.